產品列表PRODUCTS LIST
GT-JD100便攜式(shi)直(zhi)(zhi)流(liu)(liu)接(jie)(jie)地(di)故障查(cha)找儀(yi):直(zhi)(zhi)流(liu)(liu)系(xi)(xi)統(tong)(tong)(tong)接(jie)(jie)地(di)是一(yi)(yi)種易(yi)發生且對電(dian)(dian)力系(xi)(xi)統(tong)(tong)(tong)危害較大的(de)故障。直(zhi)(zhi)流(liu)(liu)系(xi)(xi)統(tong)(tong)(tong)正(zheng)極接(jie)(jie)地(di),可(ke)能造成繼(ji)電(dian)(dian)保(bao)(bao)護(hu)誤動,因為(wei)跳閘(zha)線(xian)圈接(jie)(jie)直(zhi)(zhi)流(liu)(liu)電(dian)(dian)源負極,系(xi)(xi)統(tong)(tong)(tong)再有(you)一(yi)(yi)點(dian)接(jie)(jie)地(di)或絕緣不良,可(ke)能引起(qi)保(bao)(bao)護(hu)誤動;直(zhi)(zhi)流(liu)(liu)系(xi)(xi)統(tong)(tong)(tong)負極接(jie)(jie)地(di),系(xi)(xi)統(tong)(tong)(tong)再有(you)一(yi)(yi)點(dian)接(jie)(jie)地(di)或絕緣不良,可(ke)將跳閘(zha)回路(lu)或合閘(zha)回路(lu)短路(lu),造成保(bao)(bao)護(hu)拒動,此時系(xi)(xi)統(tong)(tong)(tong)發生故障,保(bao)(bao)護(hu)的(de)拒動必然導致系(xi)(xi)統(tong)(tong)(tong)事故擴(kuo)大,同時還可(ke)能燒(shao)壞繼(ji)電(dian)(dian)器的(de)觸點(dian)或燒(shao)保(bao)(bao)險。
GT-JD100便攜式直流接地故障查找儀
一、 概 述
直(zhi)流(liu)(liu)系(xi)(xi)(xi)統(tong)接(jie)(jie)地是一種(zhong)易發生且對電(dian)力系(xi)(xi)(xi)統(tong)危害較大的故障。直(zhi)流(liu)(liu)系(xi)(xi)(xi)統(tong)正(zheng)極(ji)接(jie)(jie)地,可能造成(cheng)繼電(dian)保(bao)護(hu)(hu)誤動(dong)(dong),因為跳(tiao)閘(zha)線圈接(jie)(jie)直(zhi)流(liu)(liu)電(dian)源負極(ji),系(xi)(xi)(xi)統(tong)再(zai)有一點(dian)接(jie)(jie)地或絕緣(yuan)不良(liang),可能引起(qi)保(bao)護(hu)(hu)誤動(dong)(dong);直(zhi)流(liu)(liu)系(xi)(xi)(xi)統(tong)負極(ji)接(jie)(jie)地,系(xi)(xi)(xi)統(tong)再(zai)有一點(dian)接(jie)(jie)地或絕緣(yuan)不良(liang),可將跳(tiao)閘(zha)回路或合閘(zha)回路短路,造成(cheng)保(bao)護(hu)(hu)拒(ju)動(dong)(dong),此時系(xi)(xi)(xi)統(tong)發生故障,保(bao)護(hu)(hu)的拒(ju)動(dong)(dong)必然導(dao)致系(xi)(xi)(xi)統(tong)事故擴大,同時還(huan)可能燒壞繼電(dian)器的觸點(dian)或燒保(bao)險。
我公(gong)司自主設計制(zhi)造的便攜式直流接(jie)地(di)查找(zhao)儀(yi),能(neng)夠適(shi)用于任(ren)何電壓等級的直流系統(tong),配(pei)備(bei)了(le)高精度的檢(jian)(jian)測鉗(qian)表(biao)(biao),通過對多種信號(hao)的高效處理(li)(li)大大提高了(le)檢(jian)(jian)測范圍與(yu)抗干擾能(neng)力;采用了(le)*計算方(fang)法和模糊控制(zhi)理(li)(li)論,將被檢(jian)(jian)測支(zhi)路(lu)的絕(jue)(jue)(jue)緣程度以(yi)絕(jue)(jue)(jue)緣指數及波形的形式表(biao)(biao)示出來(lai),充分體現(xian)了(le)人工智能(neng)的*性;對于接(jie)地(di)點(dian)位置(zhi)的斷定,它們更(geng)是擁(yong)有(you)準確(que)的判斷力,每次檢(jian)(jian)測都能(neng)夠指出接(jie)地(di)點(dian)位置(zhi)相對檢(jian)(jian)測點(dian)的方(fang)向,從而快速、準確(que)地(di)實現(xian)環(huan)路(lu)接(jie)地(di)檢(jian)(jian)測。除此之外,用戶可以(yi)根(gen)據自身系統(tong)需要在絕(jue)(jue)(jue)緣告警門限(xian)值(zhi)范圍內(nei)訂制(zhi)合適(shi)的絕(jue)(jue)(jue)緣告警門限(xian)值(zhi)的設備(bei),用戶只需要將鉗(qian)表(biao)(biao)上的檔位與(yu)檢(jian)(jian)測器(qi)上的量程對應起(qi)來(lai)就能(neng)實現(xian)直流接(jie)地(di)的檢(jian)(jian)測或者是絕(jue)(jue)(jue)緣程度的分析。
GT-JD100不僅重點(dian)解決(jue)了直(zhi)流系統間接(jie)(jie)接(jie)(jie)地(di)、非(fei)金屬接(jie)(jie)地(di)、環路接(jie)(jie)地(di)、正負同時接(jie)(jie)地(di)、正負平衡接(jie)(jie)地(di)、多點(dian)接(jie)(jie)地(di)等疑難故障的準確檢測(ce),并且還能準確的顯示系統電(dian)壓(ya)、對地(di)電(dian)壓(ya)、接(jie)(jie)地(di)阻值,真(zhen)正解決(jue)了運行(xing)及檢修人員的后顧之憂。
本裝置(zhi)以(yi)系統(tong)安(an)全為(wei)首要前提,按(an)行業(ye)標準的高(gao)要求,以(yi)可(ke)靠(kao)的低頻(pin)信號方式進行檢測(ce),并在現場進行了大量的實際應用,對系統(tong)無(wu)任何影(ying)響。
GT-JD100便攜式直流接地故障查找儀
二、裝置構(gou)成及原理(li)
2. 1 裝置的(de)構成
該裝置由信號(hao)發生器(qi)(qi)、故(gu)障(zhang)檢(jian)測(ce)(ce)器(qi)(qi)和(he)信號(hao)采集(ji)器(qi)(qi)(鉗表)三(san)部分組成,信號(hao)發生器(qi)(qi)與直(zhi)流系統正(zheng)負母線(xian)和(he)地(di)相連,當直(zhi)流系統出現(xian)接地(di)故(gu)障(zhang)后,它會自動產生一個低(di)頻小信號(hao),故(gu)障(zhang)檢(jian)測(ce)(ce)器(qi)(qi)與鉗表獨(du)立于信號(hao)發生器(qi)(qi),故(gu)障(zhang)檢(jian)測(ce)(ce)器(qi)(qi)與鉗表之(zhi)間使用連接線(xian)相連,通過對待檢(jian)測(ce)(ce)支(zhi)路(lu)漏(lou)電(dian)流信號(hao)的(de)采集(ji)、分析(xi),從而(er)判(pan)斷出該支(zhi)路(lu)的(de)絕緣情況。
2.2 裝(zhuang)置的工作原理
定(ding)位裝(zhuang)置(zhi)的工作原理(li)是:當直(zhi)流系(xi)統發(fa)生接(jie)(jie)地(di)(di)(di)故(gu)障或絕緣(yuan)(yuan)降低(di)(整個直(zhi)流系(xi)統絕緣(yuan)(yuan)電(dian)阻(zu)小于報警(jing)整定(ding)值),直(zhi)流系(xi)統電(dian)壓監測(ce)(ce)裝(zhuang)置(zhi)發(fa)出(chu)警(jing)報時,將信(xin)號(hao)發(fa)生器接(jie)(jie)入直(zhi)流系(xi)統的正(zheng)、負(fu)母線(xian)和(he)地(di)(di)(di)之間。信(xin)號(hao)發(fa)生器自動判(pan)(pan)斷(duan)直(zhi)流系(xi)統電(dian)壓等級,自動判(pan)(pan)斷(duan)接(jie)(jie)地(di)(di)(di)故(gu)障的極性、接(jie)(jie)地(di)(di)(di)程度,自動分析(xi)絕緣(yuan)(yuan)監測(ce)(ce)平(ping)衡電(dian)橋回路接(jie)(jie)線(xian)方式和(he)平(ping)衡電(dian)橋電(dian)阻(zu)大小,形成信(xin)號(hao)輸(shu)出(chu)的智(zhi)能反饋,向直(zhi)流正(zheng)負(fu)母線(xian)和(he)地(di)(di)(di)間,發(fa)射適(shi)宜(yi)系(xi)統檢測(ce)(ce),對系(xi)統無影響(xiang)的低(di)頻信(xin)號(hao),并實時顯示系(xi)統電(dian)壓、正(zheng)對地(di)(di)(di)電(dian)壓、負(fu)對地(di)(di)(di)電(dian)壓和(he)系(xi)統對地(di)(di)(di)絕緣(yuan)(yuan)總阻(zu)抗。
故(gu)障(zhang)檢測器(qi)檢測各回路對(dui)地(di)(di)絕緣的(de)直(zhi)流(liu)(liu)信號(hao)漏電流(liu)(liu),并(bing)模擬(ni)顯示(shi)接地(di)(di)回路絕緣狀態,判斷(duan)出(chu)接地(di)(di)故(gu)障(zhang)回路(支路),并(bing)繼(ji)續(xu)沿故(gu)障(zhang)回路(支路)檢測出(chu)接地(di)(di)故(gu)障(zhang),將故(gu)障(zhang)點準確定位。
信號發生器、故障檢測器均采用(yong)微計算(suan)機(ji)技術,具有集成程度高,判斷(duan)(duan)速(su)度快(kuai),檢測靈敏度高、抗干(gan)擾(rao)能(neng)力(li)強(qiang)、故障定位(wei)準確等(deng)特點(dian)。在軟件(jian)處理上(shang)利(li)用(yong)了模糊(hu)控(kong)制(zhi)理論(lun)和通(tong)信的(de)(de)(de)(de)噪聲理論(lun),并(bing)依(yi)據(ju)直流系統的(de)(de)(de)(de)特點(dian)優化了算(suan)法,即使(shi)系統有大分布電(dian)容的(de)(de)(de)(de)干(gan)擾(rao)、電(dian)磁脈沖(chong)干(gan)擾(rao)和其它噪聲干(gan)擾(rao)的(de)(de)(de)(de)影響(xiang),也能(neng)準確地(di)(di)判斷(duan)(duan)出(chu)接(jie)(jie)(jie)地(di)(di)故障點(dian),為接(jie)(jie)(jie)地(di)(di)故障的(de)(de)(de)(de)查(cha)找提供了有力(li)的(de)(de)(de)(de)保(bao)障。在硬件(jian)上(shang)引進*的(de)(de)(de)(de)檢測傳感(gan)器,直流信號檢測靈敏度高達0. 1mA,可檢測150K-500K接(jie)(jie)(jie)地(di)(di)的(de)(de)(de)(de)檢測靈敏度,使(shi)多點(dian)接(jie)(jie)(jie)地(di)(di)、環(huan)路接(jie)(jie)(jie)地(di)(di)、絕緣(yuan)普遍降(jiang)低等(deng)難(nan)以解決(jue)的(de)(de)(de)(de)問題迎(ying)刃而(er)解。
三、裝(zhuang)置主要特點
1.高精度采樣鉗表
該裝置(zhi)采用了高分辨(bian)率(lv)(0. 1mA)信號采樣直流鉗表,能(neng)夠實現對多點接(jie)地,高阻接(jie)地點的定位(wei);
2. 接地點方向顯示
該裝置具有接地點(dian)方向顯(xian)示,可以(yi)高(gao)效快(kuai)速的(de)處理復雜支路(lu)或環路(lu)中接地點(dian)的(de)定(ding)位;
3. 具有絕緣指數顯示功能
絕緣(yuan)(yuan)(yuan)指數是(shi)為分析(xi)待測支(zhi)路絕緣(yuan)(yuan)(yuan)程度(du)而引入說法,以0—100的數字(zi)(zi)形式來反映(ying)被測支(zhi)路的絕緣(yuan)(yuan)(yuan)程度(du),數字(zi)(zi)越大表示絕緣(yuan)(yuan)(yuan)越差,該指數結合高(gao)精(jing)度(du)鉗(qian)表非常有(you)利于多點接地與高(gao)阻(zu)接地的檢測。
4. 具有波形顯示功能
所謂(wei)波(bo)形(xing)顯示,即(ji)在(zai)檢測(ce)過(guo)程(cheng)中(zhong)檢測(ce)器所搜(sou)索到的信號發生器的波(bo)形(xing),其在(zai)查找(zhao)接地過(guo)程(cheng)中(zhong)有(you)非常(chang)重要(yao)的作(zuo)用(yong),合理利用(yong)檢測(ce)器中(zhong)的波(bo)形(xing)顯示,可以大幅(fu)度(du)(du)的提升設(she)備的檢測(ce)范圍與檢測(ce)精度(du)(du)以判斷的準(zhun)確度(du)(du)。
5. 操(cao)作簡單,使用(yong)方便(bian)、快速
使用時只需將鉗表鉗住待測(ce)支路,按(an)一下工作按(an)鍵,3—6S即可完成一條支路的(de)檢測(ce)。
6. 信號發生(sheng)器(qi)與(yu)檢測器(qi)不受距(ju)離限制
在復雜(za)的(de)直流(liu)系統(tong)中(zhong),信號發生器(qi)接(jie)入點可(ke)能與接(jie)地查(cha)找(zhao)點有著(zhu)很長的(de)一段距(ju)離(li)(li),不過檢測器(qi)并不受此距(ju)離(li)(li)的(de)限制,可(ke)以在同一個系統(tong)中(zhong)的(de)任何一點進行查(cha)找(zhao)。
7. 運行(xing)安全(quan)、可(ke)靠(kao)
信號發(fa)生(sheng)器是需要接入直流(liu)系(xi)統(tong)(tong)之中(zhong)的,這(zhe)就對設(she)備的安全(quan)性與根據直流(liu)系(xi)統(tong)(tong)現場的實際情況,信號發(fa)生(sheng)器可智能(neng)式產生(sheng)1.0—5.0mA 的信號電流(liu),且(qie)大(da)功率小(xiao)于0.2W,適用(yong)于各類(lei)直流(liu)系(xi)統(tong)(tong),對直流(liu)系(xi)統(tong)(tong)的安全(quan)運行(xing)、可靠運行(xing)提供了保(bao)障。
技術參(can)數(shu):
1. 可(ke)檢測接地電阻范圍
系統電壓為(wei)220V時: 0 -500KΩ
系統電壓為110V時(shi): 0 -250KΩ
系統電(dian)壓為(wei)48V時(shi): 0 -50KΩ
系統電壓為(wei)24V時: 0 -10KΩ
3. 檢測信號(hao)功率(lv) ≤ 0.2W(信號(hao)發生(sheng)器(qi)輸(shu)出功率(lv))
4. 抗對地分(fen)布電容值(zhi):
對地電(dian)容單(dan)支路≤8uF,系統對地總電(dian)容≤100uF;
5. 適用直流系統(tong)電壓:
220V±10%,110V±10%,48V±10%,24V±10%,或用戶提出其它電壓(ya)等級;
6. 環境溫度:-35℃~+55℃;
7. 相(xiang)對濕度:≤95%
8. 總質量: 2.8kg
9. 外形(xing)尺(chi)寸(包裝箱(xiang)):400x150x230(mm)