国内九一激情白浆发布_漂亮人妻裸睡被公侵犯电影_艳妇乳肉豪妇荡乳ⅩXXOO_亚洲人成无码网站

產品列表PRODUCTS LIST

首頁>產品中心>直流系統接地查找儀>直流系統接地故障測試儀>SZJC-220C直流系統(tong)接地故障測試儀
SZJC-220C直流系統接地故障測試儀

發布時間:2022-11-11

簡要描述:

SZJC-220C直流(liu)(liu)系統(tong)接(jie)(jie)地故障測試儀:是一種易發(fa)生且對電(dian)力系統(tong)危害較大(da)的故障。直流(liu)(liu)系統(tong)正極接(jie)(jie)地,可能造成繼電(dian)保護(hu)誤動(dong),因為跳閘線圈接(jie)(jie)直流(liu)(liu)電(dian)源(yuan)負極,系統(tong)再有一點接(jie)(jie)地或絕(jue)緣不良,可能引起保護(hu)誤動(dong)。

在線留言
SZJC-220C直流系統接地故障測試儀

SZJC-220C直流系統接地故障測試儀

產品(pin)介紹:

直流系(xi)(xi)統(tong)(tong)(tong)(tong)接地(di)是(shi)一種易發生(sheng)且(qie)對電(dian)力(li)系(xi)(xi)統(tong)(tong)(tong)(tong)危害較大(da)的(de)故(gu)障。直流系(xi)(xi)統(tong)(tong)(tong)(tong)正極接地(di),可能(neng)造(zao)(zao)成(cheng)繼電(dian)保(bao)護(hu)誤動(dong),因為跳閘(zha)(zha)線圈(quan)接直流電(dian)源(yuan)負(fu)極,系(xi)(xi)統(tong)(tong)(tong)(tong)再有(you)一點接地(di)或(huo)絕(jue)緣(yuan)不(bu)良,可能(neng)引起保(bao)護(hu)誤動(dong);直流系(xi)(xi)統(tong)(tong)(tong)(tong)負(fu)極接地(di),系(xi)(xi)統(tong)(tong)(tong)(tong)再有(you)一點接地(di)或(huo)絕(jue)緣(yuan)不(bu)良,可將跳閘(zha)(zha)回(hui)路(lu)或(huo)合閘(zha)(zha)回(hui)路(lu)短路(lu),造(zao)(zao)成(cheng)保(bao)護(hu)拒動(dong),此時(shi)系(xi)(xi)統(tong)(tong)(tong)(tong)發生(sheng)故(gu)障,保(bao)護(hu)的(de)拒動(dong)必然導致系(xi)(xi)統(tong)(tong)(tong)(tong)事故(gu)擴(kuo)大(da),同(tong)時(shi)還可能(neng)燒壞繼電(dian)器的(de)觸點或(huo)燒保(bao)險。

直流(liu)接地故障(zhang)(zhang)檢(jian)測儀(yi)是(shi)新(xin)一代直流(liu)接地故障(zhang)(zhang)測試儀(yi)。它能(neng)夠適(shi)用于任(ren)何電壓等級的(de)(de)(de)(de)直流(liu)系統,配(pei)備(bei)了高精度的(de)(de)(de)(de)檢(jian)測鉗表,通(tong)過對(dui)多種信號(hao)的(de)(de)(de)(de)高效(xiao)處理(li)大(da)大(da)提高了檢(jian)測范(fan)圍與抗干擾能(neng)力;采用了*的(de)(de)(de)(de)算法和*的(de)(de)(de)(de)模糊控制計(ji)算理(li)論,將(jiang)被檢(jian)測絕(jue)(jue)(jue)緣支路的(de)(de)(de)(de)絕(jue)(jue)(jue)緣狀(zhuang)況(kuang)以(yi)數值(zhi)的(de)(de)(de)(de)形式表示出(chu)來(lai),充分體現了人工智能(neng)的(de)(de)(de)(de)*性(xing);對(dui)于直流(liu)系統絕(jue)(jue)(jue)緣下降或發生(sheng)接地位(wei)置(zhi)的(de)(de)(de)(de)斷定(ding),具有準確(que)的(de)(de)(de)(de)判斷力。

直流接(jie)(jie)地故(gu)障(zhang)檢測(ce)(ce)儀不僅(jin)重點解決(jue)了(le)直流系統間接(jie)(jie)接(jie)(jie)地、非金(jin)屬接(jie)(jie)地、環路接(jie)(jie)地、正負同時接(jie)(jie)地、正負平衡接(jie)(jie)地、多點接(jie)(jie)地等(deng)疑難故(gu)障(zhang)的(de)準(zhun)確(que)檢測(ce)(ce),并且還(huan)能準(zhun)確(que)的(de)顯示系統電(dian)壓、對(dui)地電(dian)壓、接(jie)(jie)地阻值,真(zhen)正解決(jue)了(le)運行及(ji)檢修人員的(de)后顧之憂。 

SZJC-220C直(zhi)(zhi)流(liu)(liu)接地故(gu)(gu)(gu)障(zhang)檢測(ce)(ce)儀由信(xin)(xin)號發(fa)(fa)(fa)生器(qi)(qi)(qi)和信(xin)(xin)號采集接收器(qi)(qi)(qi)二部分(fen)組成,信(xin)(xin)號發(fa)(fa)(fa)生器(qi)(qi)(qi)與直(zhi)(zhi)流(liu)(liu)系統正(zheng)負母線和地相連(lian),當直(zhi)(zhi)流(liu)(liu)系統出現接地故(gu)(gu)(gu)障(zhang)后(hou),它會自動產生一個低(di)頻小信(xin)(xin)號,故(gu)(gu)(gu)障(zhang)檢測(ce)(ce)器(qi)(qi)(qi)與鉗表獨立于信(xin)(xin)號發(fa)(fa)(fa)生器(qi)(qi)(qi),故(gu)(gu)(gu)障(zhang)檢測(ce)(ce)器(qi)(qi)(qi)與鉗表之間(jian)使用連(lian)接線相連(lian),通過對待檢測(ce)(ce)支路(lu)漏電流(liu)(liu)信(xin)(xin)號的(de)采集、分(fen)析(xi),從而判斷出該支路(lu)的(de)絕緣情(qing)況。    

SZJC-220C直流系統接地故障測試儀

功(gong)能特點:

1.定位查找金屬接(jie)(jie)地、非金屬接(jie)(jie)地、環路接(jie)(jie)地、正負(fu)同時接(jie)(jie)地、正負(fu)平衡接(jie)(jie)地、多點接(jie)(jie)地; 

2.測(ce)量(liang)顯示直流系統(tong)電(dian)壓,對地電(dian)壓、接地阻值; 

3.高(gao)精(jing)度采樣鉗表,對(dui)間接接地,高(gao)阻接地點定位準確可靠; 

4.高效快(kuai)速的(de)處理復雜支路或環(huan)路中接(jie)地點的(de)定位; 

5.具有絕緣指數顯示(shi)功(gong)能(neng); 

6.具有(you)波形顯示功能; 

7.操作簡(jian)單,使用方(fang)便(bian),快速; 

8.信號發生器與檢測(ce)器不受距離(li)限制; 

9.運行安(an)全,可靠。

主要技(ji)術參數:

1. 直流電壓檢測范(fan)圍:24V 48V 110V 220V

2. 接地電阻(zu)范圍:  0-10K 0-50K 0-100K 0-200K

3. 分布電容(rong)(rong):支路對地(di)電容(rong)(rong)≤8μ F 系統對地(di)總電容(rong)(rong)≤100μ F

4.信號發生器(qi)功率:0.2W

5.環(huan)境(jing)溫度 -35℃-+55℃           

6.相對溫度 ≤95%           

7.外形尺寸(cun) 460×240×120mm 

8.重量   2.2kg