產品列表PRODUCTS LIST
WX-ZJD直(zhi)流接(jie)地定點儀:該(gai)儀表由信號(hao)發(fa)生器(qi)、故障檢測(ce)器(qi)和信號(hao)采(cai)集器(qi)(鉗表)三部分組(zu)成(cheng),信號(hao)發(fa)生器(qi)與(yu)直(zhi)流系(xi)統正(zheng)負母線(xian)和地相(xiang)連,當直(zhi)流系(xi)統出現(xian)接(jie)地故障后,它會自動產生一個低頻小信號(hao),故障檢測(ce)器(qi)與(yu)鉗表獨(du)立于(yu)信號(hao)發(fa)生器(qi),故障檢測(ce)器(qi)與(yu)鉗表之間使用連接(jie)線(xian)相(xiang)連,通(tong)過對(dui)待檢測(ce)支路漏(lou)電流信號(hao)的采(cai)集、分析,從而判斷出該(gai)支路的絕緣情(qing)況(kuang)。
WX-ZJD直流接地定點儀
一、概 述
直流(liu)系(xi)(xi)統(tong)(tong)(tong)接地是(shi)一種易發生且對(dui)電(dian)力系(xi)(xi)統(tong)(tong)(tong)危害較大的故障(zhang)。直流(liu)系(xi)(xi)統(tong)(tong)(tong)正(zheng)極接地,可能(neng)造成(cheng)繼電(dian)保(bao)護誤動(dong),因為跳閘線圈接直流(liu)電(dian)源負(fu)極,系(xi)(xi)統(tong)(tong)(tong)再有一點(dian)接地或(huo)絕(jue)緣不良(liang),可能(neng)引起(qi)保(bao)護誤動(dong);直流(liu)系(xi)(xi)統(tong)(tong)(tong)負(fu)極接地,系(xi)(xi)統(tong)(tong)(tong)再有一點(dian)接地或(huo)絕(jue)緣不良(liang),可將跳閘回路(lu)或(huo)合(he)閘回路(lu)短路(lu),造成(cheng)保(bao)護拒動(dong),此時系(xi)(xi)統(tong)(tong)(tong)發生故障(zhang),保(bao)護的拒動(dong)必然導(dao)致(zhi)系(xi)(xi)統(tong)(tong)(tong)事故擴大,同時還(huan)可能(neng)燒壞繼電(dian)器的觸點(dian)或(huo)燒保(bao)險。
我(wo)公司自主設計制造的(de)(de)(de)(de)便(bian)攜式直(zhi)(zhi)流接地(di)查(cha)找(zhao)儀,能(neng)(neng)(neng)夠適用于任何電壓(ya)等級的(de)(de)(de)(de)直(zhi)(zhi)流系(xi)統(tong),配備(bei)了高精度(du)的(de)(de)(de)(de)檢(jian)測(ce)(ce)鉗表,通過對多種信號的(de)(de)(de)(de)高效處理大(da)(da)大(da)(da)提高了檢(jian)測(ce)(ce)范(fan)(fan)圍與抗干擾能(neng)(neng)(neng)力;采用了*計算方法和模糊控制理論,將被檢(jian)測(ce)(ce)支路的(de)(de)(de)(de)絕(jue)緣(yuan)程度(du)以(yi)絕(jue)緣(yuan)指(zhi)(zhi)數及(ji)波形的(de)(de)(de)(de)形式表示出(chu)來(lai),充分體現(xian)(xian)了人工智(zhi)能(neng)(neng)(neng)的(de)(de)(de)(de)*性;對于接地(di)點位置(zhi)的(de)(de)(de)(de)斷定,它們更是擁有(you)準(zhun)確(que)的(de)(de)(de)(de)判斷力,每次檢(jian)測(ce)(ce)都能(neng)(neng)(neng)夠指(zhi)(zhi)出(chu)接地(di)點位置(zhi)相(xiang)對檢(jian)測(ce)(ce)點的(de)(de)(de)(de)方向,從而(er)快速(su)、準(zhun)確(que)地(di)實現(xian)(xian)環路接地(di)檢(jian)測(ce)(ce)。除此(ci)之外,用戶(hu)可以(yi)根據自身系(xi)統(tong)需要在絕(jue)緣(yuan)告警(jing)門限(xian)(xian)值范(fan)(fan)圍內訂制合適的(de)(de)(de)(de)絕(jue)緣(yuan)告警(jing)門限(xian)(xian)值的(de)(de)(de)(de)設備(bei),用戶(hu)只需要將鉗表上的(de)(de)(de)(de)檔位與檢(jian)測(ce)(ce)器上的(de)(de)(de)(de)量(liang)程對應起來(lai)就能(neng)(neng)(neng)實現(xian)(xian)直(zhi)(zhi)流接地(di)的(de)(de)(de)(de)檢(jian)測(ce)(ce)或者是絕(jue)緣(yuan)程度(du)的(de)(de)(de)(de)分析。
此儀表不僅重點解(jie)(jie)決(jue)(jue)了直流系(xi)統間接(jie)接(jie)地(di)、非金屬接(jie)地(di)、環路接(jie)地(di)、正負同時接(jie)地(di)、正負平衡接(jie)地(di)、多點接(jie)地(di)、、等疑難(nan)故障的(de)準確檢(jian)測,并(bing)且還能準確的(de)顯示系(xi)統電(dian)壓、對滴電(dian)壓、接(jie)地(di)阻值,,真正解(jie)(jie)決(jue)(jue)了運(yun)行及(ji)檢(jian)修人(ren)員(yuan)的(de)后(hou)顧之憂(you)。
本(ben)儀(yi)表以系(xi)統安全(quan)為首要前(qian)提,按(an)行業標準(zhun)的高要求,以可靠(kao)的低頻信(xin)號(hao)方式進行檢測,并在現場進行了大(da)量(liang)的實際應(ying)用,對系(xi)統無任何影(ying)響。
WX-ZJD直流接地定點儀
二. 儀表(biao)的構成
該(gai)儀表由信號(hao)發(fa)生器、故障檢測器和(he)信號(hao)采(cai)集(ji)器(鉗表)三部分(fen)組成,信號(hao)發(fa)生器與(yu)直流系統正負母線(xian)(xian)和(he)地相連,當直流系統出(chu)現接地故障后,它(ta)會自(zi)動(dong)產生一(yi)個(ge)低頻(pin)小信號(hao),故障檢測器與(yu)鉗表獨立于信號(hao)發(fa)生器,故障檢測器與(yu)鉗表之間使用連接線(xian)(xian)相連,通過對(dui)待檢測支路漏電流信號(hao)的采(cai)集(ji)、分(fen)析,從而判斷出(chu)該(gai)支路的絕(jue)緣情(qing)況。
三(san)、儀表的工(gong)作原理
定位儀表的(de)工(gong)作原(yuan)理是:當(dang)直(zhi)流(liu)(liu)系(xi)(xi)統(tong)(tong)發生(sheng)接(jie)地(di)故(gu)(gu)障(zhang)或絕(jue)(jue)緣(yuan)(yuan)降低(整個(ge)直(zhi)流(liu)(liu)系(xi)(xi)統(tong)(tong)絕(jue)(jue)緣(yuan)(yuan)電(dian)(dian)(dian)(dian)阻小(xiao)(xiao)于報(bao)警整定值),直(zhi)流(liu)(liu)系(xi)(xi)統(tong)(tong)電(dian)(dian)(dian)(dian)壓監測儀表發出警報(bao)時,將(jiang)信(xin)(xin)(xin)號發生(sheng)器接(jie)入直(zhi)流(liu)(liu)系(xi)(xi)統(tong)(tong)的(de)正(zheng)、負母線(xian)和(he)(he)地(di)之間。信(xin)(xin)(xin)號發生(sheng)器自動(dong)判斷直(zhi)流(liu)(liu)系(xi)(xi)統(tong)(tong)電(dian)(dian)(dian)(dian)壓等級,自動(dong)判斷接(jie)地(di)故(gu)(gu)障(zhang)的(de)極性、接(jie)地(di)程度,自動(dong)分(fen)析(xi)絕(jue)(jue)緣(yuan)(yuan)監測平衡電(dian)(dian)(dian)(dian)橋回路接(jie)線(xian)方(fang)式和(he)(he)平衡電(dian)(dian)(dian)(dian)橋電(dian)(dian)(dian)(dian)阻大小(xiao)(xiao),形成信(xin)(xin)(xin)號輸出的(de)智(zhi)能反(fan)饋,向直(zhi)流(liu)(liu)正(zheng)負母線(xian)和(he)(he)地(di)間,發射適宜(yi)系(xi)(xi)統(tong)(tong)檢測,對(dui)系(xi)(xi)統(tong)(tong)無影響(xiang)的(de)低頻信(xin)(xin)(xin)號,并實時顯示系(xi)(xi)統(tong)(tong)電(dian)(dian)(dian)(dian)壓、正(zheng)對(dui)地(di)電(dian)(dian)(dian)(dian)壓、負對(dui)地(di)電(dian)(dian)(dian)(dian)壓和(he)(he)系(xi)(xi)統(tong)(tong)對(dui)地(di)絕(jue)(jue)緣(yuan)(yuan)總阻抗。
故(gu)障(zhang)檢測器(qi)檢測各回(hui)路(lu)(lu)對地絕緣的(de)直(zhi)流信號漏電流,并模(mo)擬顯示接(jie)地回(hui)路(lu)(lu)絕緣狀態,判斷出接(jie)地故(gu)障(zhang)回(hui)路(lu)(lu)(支路(lu)(lu)),并繼續沿故(gu)障(zhang)回(hui)路(lu)(lu)(支路(lu)(lu))檢測出接(jie)地故(gu)障(zhang),將(jiang)故(gu)障(zhang)點準確定位。
信(xin)(xin)號(hao)發生器、故(gu)(gu)障(zhang)(zhang)檢(jian)測(ce)器均采(cai)用(yong)微計(ji)算(suan)機技術,具有集成程度高,判斷(duan)速(su)度快,檢(jian)測(ce)靈(ling)敏度高、抗干擾(rao)能力強、故(gu)(gu)障(zhang)(zhang)定位準確等特(te)點(dian)。在(zai)軟件處理上(shang)利用(yong)了(le)模糊控(kong)制理論和(he)通信(xin)(xin)的噪聲理論,并依據直流系統的特(te)點(dian)優化(hua)了(le)算(suan)法,即使(shi)系統有大(da)分布電容的干擾(rao)、電磁(ci)脈沖(chong)干擾(rao)和(he)其它噪聲干擾(rao)的影響(xiang),也能準確地判斷(duan)出接地故(gu)(gu)障(zhang)(zhang)點(dian),為接地故(gu)(gu)障(zhang)(zhang)的查找提供(gong)了(le)有力的保(bao)障(zhang)(zhang)。在(zai)硬件上(shang)引進*的檢(jian)測(ce)傳感器,直流信(xin)(xin)號(hao)檢(jian)測(ce)靈(ling)敏度高達0. 1mA,可檢(jian)測(ce)150K-500K接地的檢(jian)測(ce)靈(ling)敏度,使(shi)多點(dian)接地、環路接地、絕緣普遍降低(di)等難以解(jie)決的問題迎刃而解(jie)。
四(si)、主要特點
1.高精度采樣鉗表(biao)
該儀表采(cai)(cai)用了(le)高分辨率(0. 1mA)信號(hao)采(cai)(cai)樣直流(liu)鉗表,能夠實現對多點接地,高阻(zu)接地點的(de)定位;
2. 接地點方向顯示
該(gai)儀(yi)表(biao)具有(you)接地點方(fang)向(xiang)顯(xian)示功(gong)能,包(bao)括:液晶屏顯(xian)示、指(zhi)示燈(deng)指(zhi)示、語音提示三種(zhong)方(fang)向(xiang)顯(xian)示方(fang)式(shi),可以(yi)高(gao)效快速(su)的(de)處理復雜(za)支路(lu)或環路(lu)中接地點的(de)定位
3. 具(ju)有絕緣指數(shu)顯(xian)示功能
絕(jue)緣指(zhi)數是為分析待測(ce)支(zhi)路絕(jue)緣程度(du)而(er)引入(ru)說(shuo)法(fa),以0—100的(de)數字形式來反映(ying)被測(ce)支(zhi)路的(de)絕(jue)緣程度(du),數字越(yue)大表示絕(jue)緣越(yue)差,該指(zhi)數結合高精度(du)鉗(qian)表非常有利于多點接地(di)與高阻接地(di)的(de)檢測(ce)。
4. 具有(you)波形顯示功能(neng)
所謂波(bo)形(xing)顯(xian)示(shi),即在檢(jian)(jian)(jian)測(ce)(ce)過程(cheng)中(zhong)檢(jian)(jian)(jian)測(ce)(ce)器(qi)所搜索到的(de)信號(hao)發生(sheng)器(qi)的(de)波(bo)形(xing),其在查找(zhao)接地過程(cheng)中(zhong)有非常重要(yao)的(de)作用(yong),合理利(li)用(yong)檢(jian)(jian)(jian)測(ce)(ce)器(qi)中(zhong)的(de)波(bo)形(xing)顯(xian)示(shi),可以大幅度的(de)提升(sheng)設(she)備的(de)檢(jian)(jian)(jian)測(ce)(ce)范圍與檢(jian)(jian)(jian)測(ce)(ce)精度以判斷的(de)準確度。
5、多量程轉(zhuan)換功能
儀表具(ju)有多(duo)量程(cheng)轉換功能,在測(ce)試(shi)過程(cheng)可以轉換不同量程(cheng),可以大幅(fu)度的提升設備的檢(jian)測(ce)范圍與檢(jian)測(ce)精度以判斷的準確度。
6. 操作(zuo)簡單(dan),使用(yong)方(fang)便、快速(su)
使用時只需將鉗表鉗住待測支(zhi)(zhi)路(lu),按(an)一下工作按(an)鍵,3—6S即可(ke)完成一條支(zhi)(zhi)路(lu)的檢(jian)測。
7. 信號發(fa)生器與檢(jian)測器不受距離限(xian)制
在(zai)復雜的(de)(de)直流系(xi)(xi)統中,信(xin)號發(fa)生器接入點(dian)可能與接地查找(zhao)(zhao)點(dian)有著很長的(de)(de)一(yi)段距(ju)離,不過檢(jian)測器并不受此距(ju)離的(de)(de)限制,可以在(zai)同一(yi)個(ge)系(xi)(xi)統中的(de)(de)任何一(yi)點(dian)進行查找(zhao)(zhao)。
8. 運(yun)行安全、可靠
信號發生器是需要接入直流系統之中的,這就對設備的安全性與根據直流系統現場的實際情況,信號發生器可智能式產生1.0—5.0mA 的信號電流,且大功率小于0.2W,適用于各類直流系統,對直流系統的安全運行、可靠運行提供了保障。
五(wu)、主(zhu)要技術指標
1. 可檢測接地電阻范圍(wei)
系統電壓為220V時: 0 -500KΩ
系統電(dian)壓為110V時: 0 -250KΩ
系統電壓為48V時: 0 -50KΩ
系統電壓為24V時: 0 -10KΩ
3. 檢測信(xin)號功(gong)率(lv) ≤ 0.2W(信(xin)號發生器輸出功(gong)率(lv))
4. 抗對地分布電容值(zhi):
對地電容(rong)單支路≤8uF,系統對地總電容(rong)≤100uF;
5. 適用直流系統電壓(ya):
220V±10%,110V±10%,48V±10%,24V±10%,或用戶提出其它電壓(ya)等級;
6. 環境溫度:-35℃~+55℃;
7. 相對(dui)濕度(du):≤95%
8. 總質量: 0.9kg
9. 外(wai)形尺寸:200x100x32(mm)